Design
Review of CPA and HV Feed-Through for SBND
June 6, 2016
Charge
The Committee is
to conduct a technical review of the Cathode Plane
Assemblies (CPA) and High Voltage (HV) feed-through
subsystems to assess their readiness for prototyping tests and
fabrications. Nominal SBND operation requires CPA to
hold 100KV for providing drift field of 500V/cm while keeping
electrical field everywhere below 30KV/cm. The design
voltage is 150KV for high voltage feed-through and CPA
components for safety overhead. The review team is asked
to examine the designs and address the following questions:
- Are the
technical specifications of the subsystems adequately
defined? Do the key design parameter follow from
them?
- Are
engineering documentations including structural and
electrostatic FEA analysis sufficient enough to support
the fabrication, installation and operation of the
subsystems?
- Are
planned prototyping steps and QA/QC tests adequate to
address any potential design issue especially on the
electrostatic calculation?
- Are the
designs presented sufficient enough to support the start
of prototyping testings and fabrications?
The committee should
present its findings, comments, and recommendations as well as
answers to the above questions in a written report within 2
weeks of the actual review.