Design Review of  CPA and HV Feed-Through for SBND

    June 6, 2016

 Charge

The Committee is to conduct a technical review of  the Cathode Plane Assemblies (CPA) and High Voltage (HV) feed-through  subsystems to assess their readiness for prototyping tests and fabrications.  Nominal SBND operation requires CPA to hold 100KV for providing drift field of 500V/cm while keeping electrical field everywhere below 30KV/cm.  The design voltage is 150KV for high voltage feed-through and CPA components for safety overhead.  The review team is asked to examine the designs and address the following questions:
The committee should present its findings, comments, and recommendations as well as answers to the above questions in a written report within 2 weeks of the actual review.